Laser Cooling

Laser Cooling

Laser cooling is critical because lasers are known for a high heat flux and high ambient temperatures.  These high temperatures require cooling precision for optimum beam quality and to prevent vibrations in the laser head.  BV Thermal Systems Recirculating Chillers are used to remove heat from laser systems to prevent overheating of critical components and to extend the life and accuracy of the laser.

Utilization of heat transfer fluids along with a closed-loop system controls the temperature which results in maintaining the shape and beam of the laser. Designed for long-term use, the environmentally friendly, quiet and cost effective Chillers for Lasers provide quality cooling at a consistent flow rate and temperature.

Laser Cooling Specifications

MODEL MC025 MC033
Cooling Capacity 861 watts @ 20°C 1119 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +27°c +5°c to +27°c
Pump 2.2 GPM to 99 PSI 2.2 GPM to 99 PSI
Reservoir Volume 1.3 gal 1.3 gal
Dimensions (w x d x h) in 14.5 x 22 x 29 14.5 x 22 x 29
Power Requirements 115V, 9A 115V, 12A
Weight (lbs) 130 130


MODEL MC050 MC075
Cooling Capacity 1702 watts @ 20°C 2681 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +27°c +5°c to +27°c
Pump 2.2 GPM to 99 PSI 2.2 GPM to 99 PSI
Reservoir Volume 1.3 gal 1.3 gal
Dimensions (w x d x h) in 14.5 x 22 x 29 14.5 x 22 x 29
Power Requirements 230V, 8A 230V, 10A
Weight (lbs) 142 182


MODEL MC100 MC150
Cooling Capacity 3575 watts @ 20°C 5480 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +30°c +5°c to +30°c
Pump 2.2 GPM to 99 PSI 2.2 GPM to 99 PSI
Reservoir Volume 1.3 gal 2 gal
Dimensions (w x d x h) in 14.5 x 22 x 29 36 x 27 x 29.75
Power Requirements 230V, 12A 230V, 20A
Weight (lbs) 258 270

 


MODEL MC200 MC300
Cooling Capacity 6,916 watts @ 20°C 10,492 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +30°c +5°c to +30°c
Pump 4.0 GPM to 99 PSI 4.0 GPM to 99 PSI
Reservoir Volume 7 gal 7 gal
Dimensions (w x d x h) in 38 x 32 x 39 38.5 x 32 x 39
Power Requirements 230V, 17A 230V, 20A
Weight (lbs) 404 442


MODEL MC400 MC500
Cooling Capacity 13,247 watts @ 20°C 117,614 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +30°c +5°c to +30°c
Pump 10 GPM to 40 PSI 10 GPM to 40 PSI
Reservoir Volume 7 gal 7 gal
Dimensions (w x d x h) in 48.5 x 33 x 48 48.5 x 33 x 48
Power Requirements 230V-3, 16A 230V-3, 20A
Weight (lbs) 484 531


MODEL MC600 MC800
Cooling Capacity 20,955 watts @ 20°C 25,644 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +30°c +5°c to +30°c
Pump 10 GPM to 40 PSI 10 GPM to 40 PSI
Reservoir Volume 7 gal 7 gal
Dimensions (w x d x h) in 65 x 45 x 42.25 65 x 45 x 42.25
Power Requirements 230V-3, 22A 230V-3, 26A
Weight (lbs) 720 825


MODEL MC1000 MC1500
Cooling Capacity 33,704 watts @ 20°C 59,700 watts @ 20°C
Stability ±0.1°C ±0.1°C
Temperature Range +5°c to +30°c +5°c to +30°c
Pump 10 GPM to 40 PSI 20 GPM to 40 PSI
Reservoir Volume 7 gal 7 gal
Dimensions (w x d x h) in 65 x 45 x 42.25 65 x 45 x 42.25
Power Requirements 460V-3, 20A 460V-3, 28A
Weight (lbs) 955 1100

Features

  • PLC Driven – no proprietary PC boards
  • External pressure – flow adjustment
  • Touch screen control with safety package (optional)
  • Hot gas bypass
  • Level, flow & temperature remote signals
  • Corrosion free wetted surfaces
  • Adjustable high & low temperature alarms
  • Stainless steel heat exchanger
  • Refrigerant receiver with access valve
  • Hard brazed joints
  • Liquid refrigerant sightglass for “at a glance” diagnosis
  • DIN rail components for easy service and safety
  • Remote status signal
  • O-Ring seal fittings

About Laser Cooling

Laser Systems require Chillers that provide consistent flow and pressure to the system while maintaining control of the coolant.  The Recirculating Chillers from BV Thermal Systems  provide accurate laser cooling and offer continuous cooling with temperature from +5° to +30°C.  Featuring a low profile design with high quality locking casters, the Chillers for Lasers provide a small footprint with exceptional performance and unmatched reliability.  You may rely on the BV Thermal Chillers for precise and dependable Laser Cooling and to ensure that appropriate cooling system pressure is maintained thereby eliminating vibrations in the laser head.

BV Thermal Systems offers numerous standard models of chillers suitable for  laser cooling  (portable and rack mount) with standard sizes ranging from 828 watts to 52,000 watts, a -35°C to +50°C temperature range and a ±0.1°C temperature accuracy.   The reliable and accurate recirculating chillers are totally customizable from coolant (water, deionized (DI) water, EGW, PGW, etc.), capacity, flow rate, piping and controller.  Standard features include: Auto tuning PID Controller, Hot Gas By-Pass Valve, Adjustable High and Low Temperature Alarms and Liquid Filled Pressure Gauge.  Every chiller that is utilized for laser cooling (standard or custom) is equipped with a one year warranty on parts and service.

Manufactured and thoroughly tested in the United States the chillers feature a hot gas by-pass which allows for greater stability and thermal protection for the pump, motor and compressor. With simplicity in design and operation, the BV Thermal Systems Chillers used for laser cooling are designed to provide years of reliable liquid temperature control.

With environmentally friendly CFC refrigerant all of our Chillers feature corrosion free wetted surfaces.  With the largest selection of options in the industry, the Chillers may be designed and manufactured to your exact requirements and specifications.

Fill out my online form.